HeartBug
Click
Auto
01 / 10
10s
HeartBug device held between fingers
New Standard

The New Paradigm

In Long Term Cardiac Monitoring

Australia's sole provider of 28-day continuous wearable ECG monitoring

Up to 28 Days Live Alerts 3 Layers of Review
Days of Monitoring
Extended
Non-Invasive
Cardiac Monitoring
HeartBug device
Indications for Use

Who Can Have a HeartBug?

Hover or tap a node
HeartBug
·

Select a node to view details

    Indication Statement

    HeartBug is for the investigation of: (i) episodes of suspected intermittent cardiac arrhythmia or episodes of syncope; or (ii) suspected intermittent cardiac arrhythmia in a patient who has had a previous cerebrovascular accident, is at risk of cerebrovascular accident or has had one or more previous transient ischemic attacks.

    One Patient · One Monitor · Four Weeks

    Three distinct, clinically actionable arrhythmias —
    none of which fall inside a 24-hour window

    HeartBugWeek 1 – Day 4
    ECG strip — Atrial Fibrillation with Slow Ventricular Response
    Atrial Fibrillation with Slow Ventricular Response
    HeartBugWeek 3 – Day 20
    ECG strip — Atrial Flutter with variable ventricular conduction
    Atrial Flutter with variable ventricular conduction
    HeartBugWeek 4 – Day 27
    ECG strip — Complete Heart Block
    Complete Heart Block
    More Monitoring. More Diagnoses.

    Symptom – Rhythm Correlation in a Patient with a Previously
    “Normal” Holter

    AFibMins
    EctopicsPercentage
    Symptom Correlation
    Symptom Count ECG Comment
    Palpitations / Fluttering 13 AEBs (12), Noise (1)
      1 AEBs
    0

    High Burden of atrial ectopics on Day 17–18 — symptoms finally mapped to rhythm, weeks after the standard test window closed.

    Diagnose More AF

    How many negative Holters could this patient have had
    before the AF was diagnosed?

    AFIB · MIN/DAY28-DAY RECORDING
    Live Data Transmission

    Know Sooner. Act Sooner

    HeartBug

    Continuous transmission

    Algorithm

    Data triaged, events flagged

    Cardiac Tech Team

    All alert ECGs reviewed by human eyes

    Physician

    Alerted next business day

    Data triaged. Urgent events identified. Physician alerted.
    HeartBug Alert Protocols

    Every Alert Class, Escalated by Severity

    Email — Next Business Day
    ALERT·01Diurnal Sinus BradycardiaHeart Rate < 30 bpm
    ALERT·02New Atrial Fibrillation / Atrial FlutterNew AF
    ALERT·03AF / Atrial Flutter with Rate< 40 bpm or > 190 bpm
    ALERT·042:1 / High Grade AV Block / CHBComplete Heart Block
    ALERT·05Ventricular StandstillAsystole
    ALERT·06Significant Pauses in Rhythm> 3 seconds
    ALERT·07Accelerated Idioventricular Rhythm / VT / VF / TdPNon-Sustained & Sustained
    ALERT·08Paediatric Tachycardia> 200 bpm
    Email + Phone — Next Business Day
    ALERT·09Rapid AF / SVT EpisodesHeart Rate > 200 bpm
    ALERT·10High Grade / Complete AV BlockEscalated
    ALERT·11Prolonged Ventricular StandstillAsystole
    ALERT·12Prolonged Diurnal Pauses> 4 seconds
    ALERT·13Sustained VT / VF / TdP> 30 seconds
    HeartBug Alert Protocols

    Triaged Email Alerts — by the Next Business Day

    Triaged Alert
    From alerts@heartbug.com.au
    Pause — 3.1 sec
    Real triaged alert strip — 3.1 sec pause
    LIVE
    Asystolic pause detected, reviewed and escalated.
    Triaged Alert
    From alerts@heartbug.com.au
    AF / Flutter < 200 bpm
    Real triaged alert strip — AF / flutter
    LIVE
    Rhythm confirmed by a cardiac technician.
    Triaged Alert
    From alerts@heartbug.com.au
    Non-sustained VT
    Real triaged alert strip — non-sustained VT
    LIVE
    Ventricular ectopy escalated with supporting strips.
    Triaged Email + Phone Alert

    A 20.7 Second Sinus Arrest Patient Asleep Completely Unaware

    The indication for this HeartBug was paroxysmal AF. HeartBug found AF — immediately following a prolonged period of sinus arrest.

    Priority · Email + Phone
    From alerts@heartbug.com.au · escalated same day in this case — standard protocol: next business day
    Sinus Arrest / Pause — 20.7 sec, then AF
    Real HeartBug strip — 20.7 second sinus arrest followed by AF
    LIVE
    Detected overnight Reviewed by human eyes Decision brought forward by weeks

    Short Monitoring Misses Alerts

    • Overall diagnostic yield for ALERTS at 28 days was 28.2% — 20,998 of 74,410 monitored patients
    • Nearly 1 in 12 detected patients had an ALERT after Day 21
    • Short monitoring durations would miss a significant proportion of ALERTS
    Cumulative Detection Yield to First Alert
    Percent of Total Monitored Patients (n = 74,410)  |  Rhythms: AF, AFL, SVT, VT, Complete Heart Block, Second-Degree AV Block, Pause
    30 20 10 0 Cumulative detection yield (%) Day of monitoring 5.62% 4,183 15.93% 11,854 22.17% 16,496 26.09% 19,414 28.22% 20,998 1 7 14 21 28
    Population: Patients ≥18 years (n = 74,410)  ·  Cumulative detection yield by Day d = Patients with first ALERT up to Day d ÷ Total monitored patients
    CLOSE ✕
    Hybrid Data Review

    3 Layers of Review.
    One Trusted Report

    1Machine precision+ 2Human judgement+ 3Specialist confirmation
    1

    Algorithm-Driven Precision

    Continuous automated analysis across all 28 days.

    2

    Triaged by Cardiac Physiologists

    Human review of every alert ECG and preparation of final reports.

    3

    Confirmed by Electrophysiologists

    Specialist confirmation before the report reaches you.

    Cardiac Tech Team
    Cardiac Tech TeamLive Review · Every Alert Strip
    Gerry Kaye
    Gerry KayeMedical Director · Specialist Confirmation
    28-Day Arrhythmia Calendars

    Previous Normal Holter.
    HeartBug Delivers Correlation

    Every day of the recording mapped at a glance — burden, distribution and symptom correlation in one view.

    24-hour Holter — a snapshotShort windows miss intermittent events; symptoms and rhythm rarely line up.
    28-day HeartBug — the full pictureContinuous monitoring plus patient-tapped symptom records, correlated day by day.
    HeartBug Patient AppSymptom Log · 28 Days
    28-Day Visual Rhythm Calendar

    Every Marked Day, at a Glance

    AF / Flutter Ectopy Conduction Sinus
    Click a day Marked days hold that day's symptom record — time of onset, sensation and rhythm correlation.
    Quantifiable Daily Arrhythmia Burden

    Beyond Waveforms. Objective Numbers

    Objective numerical data for clinical diagnosis — not just strips, but daily quantified burden.

    AF Burden · Min/DayReal Report
    Real AF burden calendar chart
    Daily AF load in minutes — see exactly when episodes cluster and how burden evolves across the recording.
    Ectopics · %/DayReal Report
    Real ectopics calendar chart
    Ectopic percentage per day — objective trend line that supports treatment decisions and follow-up.
    Real Report · Click to close
    Enlarged report
    Patient Case Files

    Four Patients. Four Definitive Answers

      HeartBug Finding
      Real ECG strip
      ESCESCHeartBug
      International Guidelines — Diagnosing Atrial Fibrillation

      Longer Monitoring = Higher AF Detection

      A monitoring time lasting 2 weeks or longer is preferable to maximise the possibility of identifying individuals with AF.

      ESC

      European Society of Cardiology
      Europace (2023) 25, 185–198
      https://doi.org/10.1093/europace/euac144

      Searching for atrial fibrillation: looking harder, looking longer, and in increasingly sophisticated ways. An EHRA position paper

      24 Hours

      A snapshot

      Frequently encountered in paroxysmal disease, but limited in scope.

      14 Days

      Guideline minimum

      The established threshold where monitoring becomes clinically meaningful.

      28 Days

      HeartBug

      Double the guideline preference, maximising detection rates.

      VOLUME 12  |  ISSUE 4  |  OCTOBER 2026
      The Evidence

      CRYSTAL AF

      Extended cardiac monitoring significantly increases AF detection in patients with cryptogenic stroke.

      01

      Cryptogenic stroke

      Stroke of undetermined source, where occult AF is the leading suspect.

      02

      Duration drives detection

      The longer the monitoring window, the higher the AF yield.

      03

      Anticoagulation

      Detected AF changes therapy — antiplatelet to anticoagulant.

      04

      Stroke prevention

      Earlier detection directly reduces recurrent stroke risk.

      18 9 0 Patients with Atrial Fibrillation Detected (%) Duration of ECG Monitoring 2.2 7.4 11.6 12.3 14.8 24 Hr 1 Wk 2 Wk 3 Wk 4 Wk
      Sanna T et al. Cryptogenic Stroke and Underlying Atrial Fibrillation. NEJM, June 26 2014.
      HeartBug Database

      Time to First Diagnosis —
      Post-Stroke & TIA Patients

      HeartBug – Time to First Diagnosis

      Data on file at HeartBug – 9,345 patients referred from Stroke Units in 2024 & 2025. Time to first significant alert from HeartBug (Email or Phone); 1,495 patients with at least one significant alert.

      The Evidence

      EMBRACE

      Extended Cardiac Monitoring
      significantly increases AF Detection
      in Post Stroke or TIA patients
      with previously undetected AF.

      Gladstone D et al. Atrial Fibrillation in Patients with Cryptogenic Stroke. NEJM, June 26 2014.
      Primary outcome: AF (>30 sec) detected within 90 days of event.
      0 4 8 12 16 20 INTERVENTION 16.1% CONTROL 3.2%
      AFib · daily burden (mins) — Oct 04 → Nov 03
      0 200 400 600 458 Oct 04 Nov 03
      One day of 458 mins of AF — invisible to a 24-hour Holter on any other day.
      Primary Outcome: AF (>30 sec) detected within 90 days of event
      Intelligence in Every Beat

      In the Last 10 Years,
      HeartBug Has Detected…

      AFIB0EVENTS
      PAUSE0EVENTS
      SVT0EVENTS
      VT0EVENTS

      HeartBug detects what others may miss.

      Partner With HeartBug

      See more.
      Miss less.

      More Monitoring. More Diagnoses.

      Head Office
      HeartBug Pty Ltd
      264 Bunnerong Rd
      Hillsdale NSW 2036
      Contact
      HeartBug · 28-Day Cardiac Monitoring
      /* 0730-4 批注:按键提示 pills 与 ⓘ 感叹号按钮不再显示(CSS 留档备用) */